Shake or Stir Before Using
MasonrySaver for Block is an architectural grade product that meets all industry guidelines for selection of commercial water repellents for concrete block and concrete masonry units (CMU). This high performance penetrating blend of silane/siloxane and acrylic elastomers bonds with the minerals in blocks and CMU’s to provide long-lasting water repellency. MasonrySaver for Block is breathable, and treated surfaces show little or no change in color or appearance. Product can be used on denser material such as brick where a slight sheen or gloss is desirable. See Product Data Sheet for additional information and uses.

DIRECTIONS FOR USE:
Surface and air temperatures should be a minimum of 40°F. Do not use on asphalt-based material and surfaces. Do not apply to frozen or frost covered surfaces.  Application must be clean, sound, dry to slightly damp surfaces. Do not apply to wet or water saturated surfaces, or when rainfall is expected within six hours.

Surface Preparation: Remove dust, dirt, grease, oils, efflorescence, wax, curing compounds, coatings or other foreign matter that might block or interfere with product penetration. See Product Data Sheet for acceptable cleaning methods.

Cure new construction a minimum of twenty eight days, and at least three days after repairs or tuckpointing before applying MasonrySaver for Block. Make necessary repairs including: structural cracks, faulty roofing, coping, flashings, expansion joints, mortar joints and sealants. Provide adequate ventilation if applied indoors.

Application: Protect all adjacent glossy surfaces, paint films, windows, plant life, asphalt-based materials and all other non-targeted surface from overspray and run-down. Remove overspray from non-targeted surfaces immediately with soap and water. Apply to southern exposed areas during coolest part of day. Mix well before using. Test small area of surface before starting general application to assure desired results and coverage rates. Allow areas to dry seventy-two hours before inspection and approval by the project architect and/or building owner. Apply from bottom up using a low pressure sprayer (10-25 psi) with a fan type nozzle, or by roller with a minimum 3/8in nap. Flood surface until excess runs down six to eight inches below spray or roller pattern. For maximum penetration and desired coverage rates, a wet on wet application is recommended; retreat within three to five minutes after initial application. When treating fluted block, apply in an overlapping X pattern to ensure complete coverage of recessed surfaces. A wet treated surface may be agitated with a soft bristle scrub brush to ensure more even distribution and greater penetration. Some surfaces may require two applications to provide maximum protection. The second application should be applied as soon as the first is dry to the touch, or within two hours of the first application. The effectiveness of the second application will be reduced if it is applied after two hours.

Painting Treated Surfaces:
MasonrySaver for Block is compatible with most quality oil base paints recommended for exterior masonry surfaces. When painting over surfaces treated with MasonrySaver for Block, a small test area should be painted to ensure good adhesion and desired results.

Drying Time - Thirty minutes to two hours depending on temperature and humidity.

Clean Up - Thoroughly rinse spray equipment with clean water. Clean rollers with soap and water. Rinse thoroughly.

Storage and Disposal- Do not store below 32°F. Dispose of this container and any unused product in accordance with all federal, state and local regulations.

Helpful Tips: Protect surrounding vegetation. Wet leaves and greenery before and after application or cover with plastic. Asphaltic material may be damaged if soaked. Protect from run-off with drop cloths or other absorbent material.

Technical Assistance
: 800-860-6327
Caution: Accumulation of product on ladders, scaffolding, roofing, etc. may result in a slippery surface. Prevent overspray from accumulating. Clean surfaces as necessary.

Warranty:
Our recommendations for use of this product are based upon testing believed to be reliable. Since field conditions vary widely, the user must determine the suitability of the product for the particular use and specific method(s) of application.
The following is made in lieu of all warranties, express or implied, including implied warranties of merchantability and fitness for a particular purpose. Sellers and manufacturers only obligation shall be to replace such quantity of the product proven to be defective. Neither seller nor manufacturer shall be liable for loss or damage, direct, incidental or consequential, regardless of the legal theory asserted, including negligence and/or strict liability.
These terms may not be altered except by an agreement signed by officers of seller and manufacturer. SaverSystems, a division of Meredith Inc. offers an extended warranty program on MasonrySaver for Block. These warranties are issued on an individual job basis only and require notification to SaverSystems prior to product application, as well as compliance with the requirements of the SaverSystems limited warranty program. Contact your sales representative or SaverSystems for additional Information on extended warranties.

Coverage Guldelines:
Coverage rates will range from 40 to 125 square feet per gallon depending upon surface porosity. When treating fluted scored and split-face block, allow for reduced coverage due to increased surface area. Material requirements and desired results should always be determined by test applications.

SaverSystems, division of Meredith, inc.
1751 Sheridan St.
Richmond, IN 47374


Non-photochemically reactive
Maximum V.O.C. 50 gr/lt (.422 lbs. per/gal.)

Cautions: Keep out of reach of children. Do not take internally. Keep from freezing.
First Aid: if swallowed, drink milk or water; do not induce vomiting. Call physician immediately. For skin contact: wash thoroughly with soap and water; if irritation persists, get medical attention.


For eye contact: Flush immediately with water, then remove any contact lenses. Continue to flush eyes with water for at least fifteen minutes. See Product Data Sheet and MSDS for additional information on this product.